check euro-diesel.com => 2 LG =2; LGCountry=2
  • 2018.04.17 EURO-DIESEL (UK) LTD ARE PLEASED TO ANNOUNCE OUR 2018 WORK EXPERIENCE WEEK FOR GRADUATE ELECTRICAL ENGINEERS: 11-15 JUNE

     

    If you are currently working at a Consulting Engineers in the UK and are involved with critical power solutions or want to learn more about UPS technologies, our Workplace Secondment Week is an ideal opportunity for you to further your knowledge.

    You will spend time with our management/engineering teams and will cover the several areas. 
    Please follow this link to discover the detailed program.
    Places are limited; if you are interested in this placement, please ensure that your employer would be happy
    for you to take up this opportunity before contacting us and send an email with your contact details, CV and a brief summary of why the placement is of interest to you and how it would benefit you in your role.
    Deadline: end of business Wednesday 16/05/18.
    E: *moc*leseid-orue+ku*ofni
    NB: EDUK will confirm after the deadline if your application has been successful.
    EDUK will assist with UK travel costs – attendees to cover their own accommodation.
  • 2018.03.30 Opening of the newest EURO-DIESEL’s subsidiary in Santiago of Chile

    It’s with great honor we announce the opening of the newest EURO-DIESEL’s subsidiary in Santiago of Chile.

     [+]
  • 2017.09.29 Recertification for EURO-DIESEL UK

    EURO-DIESEL (UK) Ltd (EDUK) is pleased to announce its successful recertification to: ISO 9001 Quality Management, ISO14001 Environment Management, OHSAS 18001 Occupational H&S Management.

     [+]

  • 2017.04.10 Come and visit us at fairs and shows around the world

    Taking advantage of our worldwide network, we participate in many exhibitions about Data Center, Airport & Industry.

    Check out our next destinations!

     [+]
  • 2017.02.08 EURO-DIESEL has been rated as STRONG

    EURO-DIESEL has been rated as “STRONG” in a new analysis of Europe's 687 largest Electrical Component Manufacturers. This is the highest accolade awarded and reflects our excellent performance over the last 12 months.

     [+]

  • 2017.01.05 FORTRUST adopts Diesel Rotary UPS for backup power

    Is it a generator? A UPS? A flywheel? The new backup power systems at colocation specialist FORTRUST bring these elements together. As FORTRUST expands its Denver data center, it will use Diesel Rotary Uninterruptible Power Supply (DRUPS) from E1 Dynamics to provide emergency power during utility outages. The DRUPS unit features a diesel engine and a rotary UPS that uses kinetic energy, eliminating the need for batteries.

     [+]

DRups system advantages

Diesel rotary UPS system advantages

Even the most efficient DRUPS system consumes energy while operating in conditioning mode. The NO-BREAK KS®, however, consumes very little energy compared to the general UPS systems in the market while providing clean and conditioned power to our critical load.

 


 

Electrical Advantages

Mechanical Advantages

  •  HIGHEST EFFICIENCY

The NO-BREAK KS® is the most efficient system in the market (>96%)

 

  • RELIABILITY

The high reliability of the NO-BREAK KS® is inherent to its design. The low component count and low operational speed make the NO-BREAK KS® the UPS system with the best MTBF in the industry.

 

  • ELIMINATION OF MAINS PERTURBATIONS  

Voltage dips, spikes, switching pulses, micro-cuts, etc. are automatically eliminated at all operating modes.

 

  •  LOAD VOLTAGE REGULATION

The voltage on the protected busbar is regulated within ±1% for upstream voltage fluctuations of up to +10% / -30%.

 

  •  POWER FACTOR CORRECTION

The NO-BREAK KS® provides reactive power and increases the power factor on the mains side, eliminating the need for capacitor banks. Since the NO-BREAK KS® improves the input power factor to almost unity, this reduces your electricity bill significantly.


  •  HARMONICS FILTRATION

The NO-BREAK KS® constitutes a perfect filter against all disturbances. It protects the load from mains carrying harmonics and prevents mains disturbances caused by load harmonics.

 

  •  SHORT CIRCUITS CLEARING  

The NO-BREAK KS® allows the clearing of short circuits on downstream feeders without using the bypass.

  • SMALL FOOTPRINT

The NO-BREAK KS® can attain up to 2500 kVA (50Hz), 3000 kVA (60Hz) per unit and can save up to 50% of floor space over static UPS designs.

 

  • BRUSHLESS

The NO-BREAK KS® is totally brushless, thus eliminating the problems generated by brushes and sliprings.

 

  • UNSTRESSED BEARINGS

Maximum bearing speed is less than 1500 rpm, guaranteeing lower operating temperatures, higher efficiencies, and very long bearing life.

 

  • MONOBLOC DESIGN

The NO-BREAK KS® has a Monobloc design; all machines are directly coupled, which makes the NO-BREAK KS® extremely robust. The NO-BREAK KS® does not require critical laser alignment inspections in the factory nor on-site.

 

  • REDUNDANT STARTING SYSTEM

The NO-BREAK KS® is equipped with a redundant starting system to activate the diesel engine mechanically through the kinetic energy of the outer rotor.


More details for Mechanical Features or Electrical Features.